Analysers

Hours of Operation: Available to licensed users 24 hours 7 days a week

Cytek Aurora Spectral Cytometer

The Cytek Aurora is equipped with five lasers – UV (355nm), violet (405nm) blue (488nm), yellow (561nm) and red (640nm), three scattering channels, and up to 64 fluorescence detectors. Spectral traces of each fluorochrome are recorded and then unmixed in a highly multicolor experiment. As a result of this approach, combinations of fluorochromes that previously were incompatible to run together by conventional flow cytometric methods are now possible with this technology. As long as a fluorochrome’s spectral fingerprint is distinct from another they can be unmixed. This enables panel design of >36 colours possible.

Cytek Aurora 1 and 2 5L – Spectral Analyser

Cytek Aurora

Lasers: 5 (355nm, 405nm, 488nm, 561nm and 640nm)
Fluorescent Detectors: 64 Channels
Tubes: Polystyrene
Software: Spectroflo

For information on common fluorochromes used on the Aurora click here.

Hours of Operation: Available to licensed users 24 hours 7 days a week

BD LSR Fortessa

The LSR Fortessa’s are equipped with four and five laser lines and are capable of detecting 18 parameters; 2 scatter and 16 fluorescent detectors. Check each instrument for the configuration and the facility staff are happy to advise on fluorochrome combination feasibility and necessary controls.

photo of LSR Fortessa
LSR Fortessa

LSR Fortessa 1

Lasers: 4 (405nm,488nm, 561nm and 633nm)
PMT Detectors: 18 Fluorescent Channels
Tubes: Polystyrene
Software: FACSDiva
High Throughput Sampler (HTS) 96 well plates
Fast Analysis Rates >20,000 events per second

Configuration

Plan your panel here

LSR Fortessa

LSR Fortessa 2, 3 and 4

Lasers: 5 (355nm,405nm,488nm, 561nm and 633nm)
PMT Detectors: 18 Fluorescent Channels
Tubes: Polystyrene
Software: FACSDiva
High Throughput Sampler (HTS) 96 well plates
Fast Analysis Rates >20,000 events per second

Configuration

Plan your panel

LSR II

LSR II

Lasers: 3 (405nm, 488nm, and 633nm)
PMT Detectors: 13 Fluorescent Channels
Tubes: Polystyrene
Software: FACSDiva
Fast Analysis Rates >20,000 events per second

Configuration

Plan your panel

photo of FACS Canto II L8
FACS Canto II a and c

FACS Canto II a

Lasers: 2 (488nm and 633nm)
PMT Detectors: 7 Fluorescent Channels
Tubes: Polystyrene
Software: FACSDiva
Analysis Rate: max 10,000 events per second

Configuration

photo of FACS Canto II L7
FACS Canto II b

FACS Canto II b

Lasers: 3 (405nm,488nm and 633nm)
PMT Detectors: 8 Fluorescent Channels
Tubes: Polystyrene
Software: FACSDiva
High Throughput Sampler (HTS)
Analysis Rate: max 10,000 events per second

Configuration